Grounding Cables for Safety Line Sets

Grounding Cables are made with extra flexible strand of soft drawn #30 AWG (.01”) copper and are available in three different jackets.

Product Options Available

SKU Name Description
73310XF Clear PVC Conductor Size: #10, Conductor Typ. O.D.: .11", Jacket Typ. O.D.: .25", ASTMF855 Grade: n/a, Fault Duty 15 Cycles: n/a
7333XFB Black Conductor Size: 3/0, Conductor Typ. O.D.: .55”, Jacket Typ. O.D.: .72”, ASTMF855 Grade: 4, Fault Duty 15 Cycles: 36.0
7336XF Clear PVC Conductor Size: #6, Conductor Typ. O.D.: .21”, Jacket Typ. O.D.: .37”", ASTMF855 Grade: n/a, Fault Duty 15 Cycles: 3.5
7340XF Clear PVC Conductor Size: #2, Conductor Typ. O.D.: .33”, Jacket Typ. O.D.: .50”, ASTMF855 Grade: 1, Fault Duty 15 Cycles: 14.0
7340XFB Black Conductor Size: #2, Conductor Typ. O.D.: .33”, Jacket Typ. O.D.: .50”, ASTMF855 Grade: 1, Fault Duty 15 Cycles: 14.0
7340XFY Yellow Conductor Size: #2, Conductor Typ. O.D.: .33”, Jacket Typ. O.D.: .50”, ASTMF855 Grade: 1, Fault Duty 15 Cycles: 14.0
7341XF Clear PVC Conductor Size: 1/0, Conductor Typ. O.D.: .45”, Jacket Typ. O.D.: .64”, ASTMF855 Grade: 2, Fault Duty 15 Cycles: 21.0
7341XFB Black Conductor Size: 1/0, Conductor Typ. O.D.: .45”, Jacket Typ. O.D.: .64”, ASTMF855 Grade: 2, Fault Duty 15 Cycles: 21.0
7341XFY Yellow Conductor Size: 1/0, Conductor Typ. O.D.: .45”, Jacket Typ. O.D.: .64”, ASTMF855 Grade: 2, Fault Duty 15 Cycles: 21.0
7342XF Clear PVC Conductor Size: 2/0, Conductor Typ. O.D.: .47”, Jacket Typ. O.D.: .66”, ASTMF855 Grade: 3, Fault Duty 15 Cycles: 27.0
7342XFB Black Conductor Size: 2/0, Conductor Typ. O.D.: .47”, Jacket Typ. O.D.: .66”, ASTMF855 Grade: 3, Fault Duty 15 Cycles: 27.0
7342XFY Yellow Conductor Size: 2/0, Conductor Typ. O.D.: .47”, Jacket Typ. O.D.: .66”, ASTMF855 Grade: 3, Fault Duty 15 Cycles: 27.0
7343XF Clear PVC Conductor Size: 4/0, Conductor Typ. O.D.: .63”, Jacket Typ. O.D.: .84”, ASTMF855 Grade: 5, Fault Duty 15 Cycles: 43.0
7343XFB Black Conductor Size: 4/0, Conductor Typ. O.D.: .63”, Jacket Typ. O.D.: .84”, ASTMF855 Grade: 5, Fault Duty 15 Cycles: 43.0
7343XFY Yellow Conductor Size: 4/0, Conductor Typ. O.D.: .63”, Jacket Typ. O.D.: .84”, ASTMF855 Grade: 5, Fault Duty 15 Cycles: 43.0

Grounding Cables for Safety Line Sets Features and Benefits

The transparent flexible thermoplastic (PVC) jacketed cable allows easy inspection for strand breakage. The flexibility decreases with low temperatures. The service temperature ranges from 140º to -40ºF per ASTM F 855, Type III requirements.

The yellow (shown here) thermoplastic elastomer jacketed cable is the standard for grounding service. It provides a combination of economy, flexibility, and durability. The service temperature ranges from 200º to -50ºF per ASTM F 855, Type I requirements.

The black thermoplastic elastomer jacketed cable has a smaller diameter and thinner jacket material giving it better flexibility than the yellow cable. The service temperature ranges from 200º to -50ºF per ASTM F 855, Type I requirements.

Grounding Cables for Safety Line Sets Accessories